Error Messages from Chapter 8: Maintenance
Commands
555-233-123
A-84 Issue 4 May 2002
If the command entered is in conflict with another currently executing command,
then a message appears showing the login id of the conflicting user and the
conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
set expansion-link
Help Messages
If the system technician presses HELP after entering “set expansion-interface,” the
following message appears:
Enter board location:
[cabinet(1-3)];carrier(A-E);slot(0-20)
Error Messages
If the format of the specified expansion interface circuit pack is invalid, the
following message appears:
Port/Board invalid
If the link associated with the entered EI location is already active, the following
message appears:
EXP-INTF is already on active link
If the specified expansion interface is not configured in the system, the following
message appears:
Board not assigned
If the specified expansion interface is already the active link, the following
message appears:
EXP-INTF is already on active link
If the specified expansion interface is unable to become active, the following
message appears:
Standby EXP-INTF Link is unable to take over
If there are no maintenance objects for the specified board, the following message
appears:
No MO in this board
If the specified board is not an expansion interface board, the following message
appears:
Address is not a valid Expansion Interface Board