Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-296 Issue 4 May 2002
Field descriptions
set tone-clock
This command sets the active tone/clock for a PN that has a duplicated tone/clock
circuit pack. Technicians should reset the default active tone clock in each PN
after using the set tone-clock command. If it is not in use, a single failure can
cause an unnecessary service outage. The schedule maintenance tone-clock
switch option does not reset the tone-clock to the default active if it was not active
at the beginning of the test.
Day of the Week:
Monday through Sunday.
Day of the Month:
1-31. The system also checks for leap year.
Month:
January through December.
Year:
1970-2999
Hour:
0-23.
Minute:
0-59
Second:
The system sets this field to zero when the time of day clock is
set.
Type
Daylight-savings
= daylight savings time
Standard = standard time
Daylight Savings
Rule
The daylight savings time rule number (0 to 15). Rule 0 is no
daylight savings time, and rule 1 defaults to U.S. daylight
savings time rule.
Action/
Object Qualifier Qualifier Description Logins Defaults
Feature
Interactions
set
tone-clock
location
override
Physical location (PC) of the tone/clock to
be tested
Forces the set command into effect
regardless of the tone/clock circuit pack’s
health.
Examples:
set tone-clock 01b
set tone-clock 1b
set tone-clock 01b override
set tone-clock a
init
inads
craft
1 (one) none