REM-OFF (Remote Office)
Issue 4 May 2002
10-1457555-233-123
REM-OFF (Remote Office)
An instance of this maintenance object (REM-OFF) is associated with every
Remote Office box that is administered on the switch. This maintenance object
monitors keep alive and periodic PING test failures, and if these errors occur, they
are logged against this maintenance object.
Error Log Entries and Test to Clear Values
Notes:
a. Error Type - 1 — indicates that a PING Test to the Remote Office has
failed, and a MINOR alarm has been raised.
The PING test verifies that a path to a registered Remote Office is good.
When this error is logged, as many as 26 endpoints (associated with that
Remote Office) and several H.323 signaling groups could be out of service.
MO Name (in
Alarm Log) Alarm Level Initial Command to Run
1
1 UU is the universal cabinet number (1 for PPN, 2 or 3 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides (01 to 21).
Full Name of MO
REM-OFF MIN ping node-name/ip-address Remote Office
REM-OFF WRN ping node-name/ip-address Remote Office
Table 10-553. Analog Line Error Log Entries
Error
Type
Aux
Data
Associated
Te st
Alarm
Level
On/Off
Board Test to Clear Value
1(a) A ping test to
an endpoint
has failed
MINOR OFF ping
node-name/ip-address
257(b) See note
(b)
A keep alive
update
request has
exceeded the
time limit for
an endpoint
Log only OFF ping
node-name/ip-address