status pri-endpoint
Issue 4 May 2002
8-379555-233-123
status pri-endpoint
This command displays internal software state information for diagnosis and can
help locate facilities with which a PRI endpoint is communicating. Status
information for each of the B-channels making up the PRI endpoint display in
addition to some overall PRI endpoint information.
Output
The following example shows the output for the status pri-endpoint 22501
command and assumes the following:
PRI endpoint ports for extension 22501 are in cabinet 1, carrier B, slot 20,
circuit 1 to 6.
The ports 1 to 3 of the specified PRI endpoint are connected on an active
call to ports 13 to 15 of board in location 1B19 (cabinet 1, carrier B, slot 19).
Ports 4 and 5 of the specified PRI endpoint are idle.
Port 6 of the specified PRI endpoint is out of service, and background
maintenance testing is being performed on the port.
NOTE:
A PRI endpoint can initiate and receive a call on any one or more of the
B-channels making up the PRI endpoint.
Action/
Object Qualifier Qualifier Description Logins Defaults
Feature
Interactions
status
pri-endpoint
extension
print
PRI endpoint extension to be displayed
(see dial-plan).
Report sent to printer
Examples: status pri-endpoint 25012
status pri-endpoint 77868
status pri-endpoint 66078 print
init
inads
craft
nms
browse
none none
status pri-endpoint 22501 page 1 of 1
PRI-ENDPOINT STATUS
Extension: 22501 Width: 6
Signaling Group ID: 3 B-Channels Active: 3
Originating Auto Restoration? n B-Channels Idle: 2
Port Service State Test In Progress Connected Port
01B2001 in-service/active n 01B1913
01B2002 in-service/active n 01B1914
01B2003 in-service/active n 01B1915
01B2004 in-service/idle n
01B2005 in-service/idle n
01B2006 out-of-service-NE y