release journal-printer
Issue 4 May 2002
8-255555-233-123
release journal-printer
This command activates maintenance objects associated with a specified pms-log
or wakeup-log link. Execute hardware tests to verify that equipment is functioning.
For information on journal printer links, see ‘‘busyout pms-link’’.
For information on journal printers, see ‘‘status journal-link’’.
Feature Interactions
Specific component maintenance performed on a link sometimes conflicts with
link maintenance (busied out objects create link setup failure). Frequent link
re-setup attempts may delay faulty component recovery. For best results, use
busyout to disable attempted link re-setup.
Output
The following output example is a display of release journal-printer wakeup-log.
Field descriptions
Action/Object Qualifier Qualifier Description Logins Default
Feature
Interactions
release
journal-printer
pms-log
wakeup-log
releases links to pms printers. (1)
Releases links to wakeup logging
facilities. (0)
Examples:
release journal-printer pms-log
release journal-printer wakeup-log
init
inads
craft
nms
none see below
Port
Port address of busied out or released maintenance object.
(wakeup log = 0; pms log = 1)
Maintenance Name
Type of busied out or released maintenance object.
Alt. Name
Not applicable.
Result
Success status of a busied out object (PASS, ABORT, FAIL)
Error Code
System-generated description of a command failure.
release journal-printer wakeup-log
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
0 JRNL-LINK PASS
Command successfully completed