test signaling-group
Issue 4 May 2002
A-143 555-233-123
If the standby SPE is not available when this command is executed, then the
following message appears:
Standby SPE not available;
for information use “status system 1"
test signaling-group
Help Messages
If the system technician presses HELP after entering “test signaling-group”, the
following appears:
Enter group identifier (1-8), [’long’ or ’short’],
[’repeat’ (1-100) or ’clear’], [’schedule’]
Error Messages
If the specified group identifier is non numeric or out of range, the following
message appears:
Signaling group invalid
If the specified group identifier is not administered, the following message
appears:
No signaling group assigned
If no tests can be found for the associated MO, the following message appears:
No tests for this MO
If the software data cannot be sent to the SAT, the following message appears:
Error encountered, can’t complete request
If during the execution of a command a resource problem occurs that requires the
user to restart the command, then the following message appears:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message appears:
All maintenance resources busy; try again later