recycle carrier
Issue 4 May 2002
8-247555-233-123
recycle carrier
This command recycles power for specified carriers. When power units are
replaced in carriers, this command recycles that carrier’s power. Processor
carriers and their duplicates and EPN control carriers or SCC carriers cannot be
recycled. Carriers with active, recycled EIs, experience disrupted communications
with their cabinets. Carriers with active, recycled tone-clock boards experience
disrupted service for ports in port networks. For more details on recycling and
trouble shooting power units, refer to “Troubleshooting Control Carrier Power
Units” in Chapter 5, ‘‘Routine Maintenance Procedures’’.
Feature Interactions
Carrier “a” cannot recycle its power. When carrier “b” of the PPN contains SPE
duplication hardware, it cannot recycle its power.
Recycling maintenance objects results in:
The test tdm command accelerates retirement of these problems.
Action/
Object Qualifier Qualifier Description Logins Default
Feature
Interactions
busyout
mis
location Physical location of desired carrier.
Carrier b-e. (b not applicable for SPE
duplex PPNs)
init
inads
craft
cabinet = 1
none for
carrier
see below
Recycled component Result
Port Carriers
Interrupted service
Carriers with active
EIs
Disrupted communication with that cabinet
Carriers with active
tone-clock boards
Interrupted service for ports port network
Carrier
The list configuration command causes circuit packs to
display red LEDs and NO BOARDs.