Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-372 Issue 4 May 2002
status journal-link
The status journal-link command displays if the link is up or down. If the link is
down, the system displays the number of times the switch tries to initialize the link.
A journal printer documents automatic wake-up events, emergency access to
attendant events, and housekeeping events when the property management
system is not functional. A journal printer may also generate reports for automatic
wake-up events and emergency access events at a scheduled time. If system
configuration includes two printers, one is for housekeeping events only and the
other is for automatic wake-up events and emergency access events.
For general information on journal printer links, see the description of the ‘‘busyout
journal-printer’’ command.
Output
The following example is a display of status journal-link wakeup-log.
Field descriptions
Action/Object Qualifier Qualifier Description Logins Defaults
Feature
Interactions
status
journal-link
wakeup-l
og
pms-log
print
printer that handles automatic
wakeup and emergency access to
attendant events and scheduled
reports.
printer that handles pms down
events.
Reports print to SAT-linked printer.
Examples:
status journal-link wakeup-log
status journal-link pms-log
status journal-link pms-log print
init
inads
craft
cust
rcust
bcms
browse
none none
Link State
If extensions are administered in the System Parameters
Hospitality form, wakeup-logs or pms-log links are considered
to be administered only.
Maintenance Busy
Is maintenance testing performing on the link?
status journal-link wakeup-log
JOURNAL LINK STATUS
Link State: up
Maintenance Busy? no