Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-134 Issue 4 May 2002
enable test-number
This command enables a previously disabled test number. At the next request by
maintenance or the technician, this test number runs.
get boot-image
Use this command to view the two firmware image parameters on the TN2501AP
circuit pack.
Screen 8-13. Display Firmware Image(s) screen
Action/
Object Qualifier
Qualifier
Description Logins Defaults
Feature
Interactions
enable
test-number
number The test number to
re-enable
Example:
enable test-number
102
init
inads
craft
none display
disabled-tests
gives a list of all
disabled tests.
Action/
Object Qualifier Qualifier Description Logins Defaults
Feature
Interactions
get boot-
image
location The physical location of the
circuit pack (UUCSS).
Example
get boot-image 1C07
init
inads
craft
customer
get boot-image 1C07
DISPLAY FIRMWARE IMAGE(S)
Image 1 Image 2
Board Type: TN2501 TN2501
FW Vintage: 02 02
HW Signature: 02 02
Suffix: A A
Date: 03/02/02 03/02/01
Timestamp: 10:30:50 12:42:18
CRC Checksum: Good Good
Active Image: Yes No
Reboot Image: Yes No