list measurements
Issue 4 May 2002
A-53 555-233-123
Error Messages
If during the execution of a command a resource problem occurs that requires the
user to restart the command, then the following message appears:
Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message appears:
All maintenance resources busy, try again later
list measurements
Help Messages
If the system technician presses HELP after entering “list measurements ds1”, the
following list of options appears:
log summary
If the system technician presses HELP after entering “list measurements ds1 log”
or “list measurements ds1 summary”, the following message appears:
Enter board location: [cabinet(1-3)];carrier(A-E);slot(00-20),
[’print’ or ’schedule’]
Error Messages
If the user enters an invalid format for a board location when entering a “list
measurements ds1 log” or “list measurements ds1 summary” command, the
following error message appears:
“entered value” Invalid slot address for DS1 board
If the user enters a board location that is not a DS1 board location or the location
of an unadministered DS1 when entering a “list measurements ds1 log” or “list
measurements ds1 summary” command, the following error message appears:
DS1 board has not been administered
If the user enters anything other than “log” or “summary” following “list
measurements ds1”, the following error message appears:
“entered value” is an invalid entry; please press HELP
If the system time has not been set correctly, after entering “list measurements
ds1 log ds1_location” or “list measurements ds1 summary ds1_location” the
following error message appears:
Cannot get time from system clock