Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-270 Issue 4 May 2002
reset board
This command performs a soft reset of every specified, administered port on the
port circuit pack. Ports must be busied out before the port circuit pack resets.
!
WARNING:
This command is service disrupting and may cause extraneous alarms.
Output
The following output example is a display of reset board 1c07 and assumes that
the board in port network 1, carrier c, slot 7 is an analog board with three ports
administered.
Field descriptions
Action/Object Qualifier Qualifier Description Logins Defaults
Feature
Interactions
reset board location
repeat
number
Physical location: PCsspp
Number of times each board reset
repeats (1– 00)
Examples:
reset board 01c11
reset board c08
reset board 03d12 r 3
init
inads
craft
nms
carrier = 1
repeat
number = 1
none
Port
Port address (cabinet-carrier-slot) of the reset maintenance
object.
Maintenance Name
Type of reset maintenance object.
Alt. Name
Alternate way to identify maintenance objects.
If the Object is The field contains
station extension
trunk xxx/yyy (xxx = trunk group, yyy = member)
private CO line P/xxx (xxx = private CO line group number)
Result
Success status of a busied out object (PASS, ABORT, FAIL)
Error Code
System-generated description of a command failure.
reset board 1C07
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C07 ANL-BD 53 PASS
Command Successfully Completed