test network-control
Issue 4 May 2002
A-135 555-233-123
If during the execution of a command a resource problem occurs that requires the
user to restart the command, then the following message appears:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message appears:
All maintenance resources busy; try again later
test network-control
Help Messages
If the system technician presses HELP after entering “test network-control” the
following message appears for a simplex switch configuration:
Enter [’long’ or ’short’], [’repeat’ (1-100)
or ’clear’], [’schedule’]
For a duplex switch configuration, the following message appears:
Enter [cabinet(1)];carrier(A-B),
[’long’ or ’short’], [’repeat’ (1-100)
or ’clear’], [’schedule’]
Error Messages
If the SPE is not active, the following message appears:
Command must be executed from active SPE
If the carrier entered is invalid, the following message appears:
“entered value” is an invalid identifier;
press RETURN to execute modified command
If the NETCON board is not TN777B, the following message appears:
Must install TN777B circuit pack
If the entered standby carrier cannot be retrieved, the following message appears:
Error encountered, can’t complete request
If there aren’t any tests found for this MO, the following message appears:
No tests for this MO
If the command entered is in conflict with another currently executing command,
then a message appears showing the login id of the conflicting user and the
conflicting command. The message is as follows:
’login id’:’command’ has a command conflict