test tone-clock
Issue 4 May 2002
8-491555-233-123
test tone-clock
The test tone/clock command performs hardware diagnostic tests on a
technician-specified tone or clock circuit pack.
Action/Object Qualifier Qualifier Description Logins Defaults
Feature
Interactions
test
tone-clock
location
short
long
repeat
number
clear
schedule
PCSS
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
How many times each test in the
sequence is repeated (1-100)
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequence fails.
1
Command is validated and then a
scheduling form displays to
schedule execution of the
command. The command is then
placed in the command queue and
is executed at the specified time.
The information displayed by the
command is sent to the system
printer instead of the screen.
2
Examples:
test tone-clock 01a l
test tone-clock 01b l schedule
1 If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence.
2 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
Test
Sequence
= short;
Repeat =
1
none