Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-492 Issue 4 May 2002
Output
The responses display on a test-by-test basis with one line of data for each test
result. The following is the output for the test tone-clock 1a command.
Field descriptions
Port
The port address: cabinet-carrier-slot-circuit
Maintenance
Name
TONE-BD, TONE-PT, TDM-CLK.
Alt. Name
Not applicable.
Test No
Test being executed
Result
PASS, ABORT, FAIL, NO BOARD, DISABLED, EXTRA BD.
Error Code
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of codes by test number for each MO.
test tone-clock 1a
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01A TONE-BD 46 PASS
01A TONE-BD 52 PASS
01A TONE-PT 40 PASS
01A TONE-PT 41 PASS
01A TDM-CLK 148 PASS
01A TDM-CLK 149 PASS
01A TDM-CLK 150 PASS
01A TDM-CLK 151 PASS
01A TDM-CLK 574 PASS
Command Successfully Completed