Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-452 Issue 4 May 2002
test journal-printer
This command performs hardware diagnostics on the link between the switch and
one of the specified journal printer links. There are two types of journal printer
links: pms-log and wakeup-log. For general information on journal printer links,
see the second paragraph in the Description section of the busyout pms-link
manual pages. For information on what a journal printer is and does, see the
second paragraph in the ‘‘Output’’ section of the ‘‘status journal-link’’ manual
pages.
Action/Object Qualifier Qualifier Description Logins Defaults
Feature
Interactions
test
journal-printer
pms-log
wakeup-log
short
long
repeat
number
clear
schedule
Tests the link to the pms logging printer
(maintenance name = PMS-PRNT)
Tests the link to the wakeup logging
printer (maintenance name =
JNL-PRNT)
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
Number of times each test in the
sequence is repeated (1-100)
This option causes the test sequence
(short or long) to repeat until the alarm
(if any) is cleared or a single test in the
sequence fails.
1
Command is validated and then a
scheduling form displays to schedule
execution of the command. The
command is then placed in the
command queue and is executed at
the specified time. The information
displayed by the command is sent to
the system printer instead of the
screen.
2
Examples:
test journal-printer pms-log l
test journal-printer pms-log l
schedule
test journal-printer wakeup-log r 2
test journal-printer wakeup-log r 2
schedule
test journ pm r 3
test journ pm r 3 schedule
1 If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence.
2 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
Test
sequence =
short;
repeat = 1
See below