Error Messages from Chapter 8: Maintenance
Commands
555-233-123
A-12 Issue 4 May 2002
busyout station
Help Messages
If the system technician presses HELP after entering “busyout station,” the
following message appears:
Enter extension for an assigned station
Error Messages
If the format of the extension is incorrect, the following error message appears:
Extension invalid
If the specified extension is not administered, then the following message
appears:
Extension not assigned
If the specified extension does not belong to a station or attendant console, the
following message appears:
Extension exists but assigned to a different object
If the station port resides on an EPN that is unavailable, the following message
appears:
EPN is not available
If the station port resides on a board that is not inserted in the system, the
following message appears:
Board not assigned
If the station port resides on a board that is part of the SCI link, the following
message appears:
Cannot busyout/release part of SCI link
If the command entered is in conflict with another currently executing command,
then a message appears showing the login id of the conflicting user and the
conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires the
user to restart the command, then the following message appears:
Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message appears:
All maintenance resources busy; try again later