Error Messages from Chapter 8: Maintenance
Commands
555-233-123
A-4 Issue 4 May 2002
If during the execution of a command a resource problem occurs that requires the
user to restart the command, then the following message appears:
Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message appears:
All maintenance resources busy; try again later
busyout data-module
This command will busyout a system technician specified data module or data
channel.
Help Messages
If the system technician presses HELP after entering “busyout data-module,” the
following message appears:
Enter assigned extension
Error Messages
If the length or format of the extension is incorrect, the following error message
appears:
Extension invalid
If the specified extension is not administered, then the following message
appears:
Extension not assigned
If the specified extension is not a data module or a data channel, then the
following message appears:
Extension exists but assigned to a different object
If the EPN that contains the data module port is not available, the following
message appears:
EPN is not available
If the board containing the data module port is part of the SCI link, the following
message appears:
Cannot busyout/release part of SCI link
If the command entered is in conflict with another currently executing command,
then a message appears showing the login id of the conflicting user and the
conflicting command. The message is as follows:
’login id’:’command’ has a command conflict