Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-260 Issue 4 May 2002
release pms-link
The release pms-link command deactivates MOs that are associated with a
property management system link.These links provide asynchronous data
connections from switches to peripherals. They are composed of:
■ Far end data module
■ Simulated data channel on a NETCON board
■ Manager that initiates and maintains the link
■ Controller/protocol that services the link
Feature Interactions
Specific component maintenance performed on a link sometimes conflicts with
link maintenance, itself. (Busied out objects create link setup failure). Frequent
link re-setup attempts may delay faulty component recovery. For best results, use
busyout to disable attempted link re-setup.
Output
The following output example is a display of release pms-link.
Field descriptions
Action/Object Qualifier Qualifier Description Logins Defaults
Feature
Interactions
release
pms-link
init
inads
craft
none see below
Port
This field is left blank.
Maintenance Name
PMS-LINK
Alt. Name
Not applicable.
Result
Success status of a busied out object (PASS, ABORT, FAIL)
Error Code
System-generated description of a command failure.
release pms-link
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
PMS-LINK PASS