test shadow-link
Issue 4 May 2002
8-477555-233-123
test shadow-link
This command performs hardware diagnostics for the shadow link between the
two duplication-interface circuit packs. This command works only with High or
Critical Reliability systems. Refer to Chapter 6, ‘‘Reliability Systems: A
Maintenance Aid’’ for more details.
Action/
Object Qualifier Qualifier Description Logins Defaults
Feature
Interactions
test
shadow-link
short
long
repeat
number
clear
schedule
Both the short and long test
sequence execute only Test
#318.
How many times each test in the
sequence is repeated (1-100)
This option causes the test
sequence (short or long) to
repeat until the alarm (if any) is
cleared or a single test in the
sequence fails.
1
Command is validated and then a
scheduling form displays to
schedule execution of the
command. The command is then
placed in the command queue
and is executed at the specified
time. The information displayed
by the command is sent to the
system printer instead of the
screen.
2
Examples:
test shadow-link l
test shadow-link sh r 2
test shadow-link sh r 2
schedule
test shadow-link c
1 If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence.
2 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
Test
Sequence
= short;
Repeat = 1