Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-256 Issue 4 May 2002
release link
The release link command activates MOs associated with a specified link.
Hardware tests are executed to verify that equipment is functioning properly.
Output
The following output example is a display of release link 1.
Field descriptions
Action/
Object Qualifier Qualifier Description Logins Defaults
Feature
Interactions
release
link
link-id Number associated with each link (1–8).
1 through 4 reside on Processor Interface circuit
packs “1a1” or “1b1”
5 through 8 reside on Processor Interface circuit
pack “1a2” or “1b2.”
Examples:
release link 1
release link 8
init
inads
craft
none none
Port
Port address (cabinet-carrier-slot-circuit) of the busied out or
released maintenance object. Port address represents the
link-id.
Maintenance Name
The type of maintenance object that is being released.
Alt. Name
Not applicable.
Result
Success status of a busied out object (PASS, ABORT, FAIL)
Error Code
System-generated description of a command failure.
release link 1
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01C0301 PI-LINK PASS
Command successfully completed