Error Messages from Chapter 8: Maintenance
Commands
555-233-123
A-60 Issue 4 May 2002
If the cabinet and carrier specified are in an EPN that is not available, the
following message appears:
EPN is not available
If a cabinet number of “1” or “01” is entered and the carrier specified is “A” or “B” in
an SPE duplex system, the carrier specified is “A” in a SPE simplex system or if
the “A” carrier is specified with a cabinet other than “1” or “01, or an SCC carrier
location is given,” the following message appears:
Cannot recycle control carriers or XE carriers
If the command entered is in conflict with another currently executing command,
then a message appears showing the login id of the conflicting user and the
conflicting command. The message is as follows:
login id’:’command’ has a command conflict
refresh spe-standby
Help Messages
If the system technician presses HELP after entering “refresh spe-standby,” the
following message appears:
Entry is not required
Error Messages
If the command entered is in conflict with another currently executing command,
then a message appears showing the login id of the conflicting user and the
conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
release access-endpoint
Help Messages
If the user presses HELP after entering “release access-endpoint,” the following
message appears:
Enter assigned extension
Error Messages
If the format for the extension is incorrect, the following error message appears:
Extension invalid