Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-468 Issue 4 May 2002
Output
The following example is the output for the test pkt port-network 1 command. The
responses display on a test-by-test basis with one line of data for each test result.
Field descriptions
Port
A port network number (1-3).
Maintenance
Name
The name of maintenance object being tested.
Alt. Name
Not applicable.
Test No
The test being executed.
Result
Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Error Code
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of codes by test number for each MO.
test pkt port-network 1
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
PN 01 PKT-BUS 571 PASS
PN 01 PKT-BUS 572 PASS
PN 01 PKT-BUS 573 PASS
Command successfully completed