FL-DATA (Flash Data Consistency)
Issue 4 May 2002
10-829555-233-123
a. The Aux Data field records which SPE was active at the time the Flash
Data Consistency Test failed. An “8” in the log refers to carrier A and a “16”
refers to carrier B.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below. By clearing
error codes associated with the Memory Card Insertion Test, for example, you
may also clear errors generated from other tests in the testing sequence.
Notes:
a. See “CARD-MEM” for this test description.
b. The Flash Data Consistency Test does not run in a Standard system.
292, 324,
388, 420,
452
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/
ND
1
1 D = Destructive; ND = Nondestructive
Memory Card Insertion Test (#695) (a) X X ND
Memory Card Format and Read Test (#696) (a) X X ND
Memory Card Match Test (#697) (a) X X ND
Memory Card Write-Protected Test (#698) (a) X X ND
Memory Card Directory Recovery Test (#699) (a) X X ND
Memory Card Translation Data Integrity Test
(#694) (a)
XND
Memory Card Erase/Write/Read Test (#693) (a) X ND
Flash Data Consistency Test (#421) (b) X ND