H323-SGRP (H.323 Signaling Group)
Issue 4 May 2002
10-873555-233-123
Notes:
a. Error Type 1 represents a failure of the CLAN hardware carrying the
signaling group D-Channel. Check for errors against the CLAN-BD
maintenance object.
b. Error Type 257 tracks failures of the H.323 signaling-group PING test.
H.323 signaling-group PING test failures are documented later in this
maintenance object.
c. Error Type 513 tracks excessive round trip delay of the H.323
signaling-group PING test (if the round-trip delay exceeds 4 seconds).
d. Error Type: 770 tracks excessive latency and packet-loss from
background IP measurements collected by the Media Processor Board.
e. Error Type 1025 indicates that the signaling group has been placed into
a BYPASS condition because of IP network congestion. The signaling
group accepts incoming calls, but all outgoing calls are denied. The system
routes these calls over a secondary route, if one has been administered.
f. Error Type 1281 implies that no medpro resources are in-service to
provide media connections for the trunk members of the signaling group.
g. Error Type 1794 The Sig Group reported that the far-end has detected
excessive packet latency or loss.
h. Error Type 2049 A Keep-Alive timer is set for every registered endpoint
on the Remote Office, and the switch expects Keep-Alive update within
that timers time period. If the update does not occur, a message is
generated that causes an error to be logged against MO REM-OFF, as well
as MO H323-SGRP. Because the signaling group is still known, the error
against MO H323-SGRP generates a Minor alarm. This error is only valid if
the change signaling group form has the RRQ field set to y. This error
counter is only set if a failure has been detected by Call Processing and it
notifies maintenance software. The Keep-Alive Error Type 2049 clears only
after a registration occurs and Error Type 2305 clears.
i. Error Type 2305 indicates that the Gateway (signaling group on the
Remote Office) is unregistered. Because the signaling group is still known,
the error against MO H323-SGRP generates a Minor alarm when this
failure occurs. This error is applicable if the change signaling group form
has the RRQ field set to y.