Maintenance Object Repair Procedures
555-233-123
10-174 Issue 4 May 2002
Notes:
a. Errors of this type indicate violations of the ISDN-BRI signaling protocol.
Timers associated with certain Layer 3 messages have expired before a
required response was received. In the following table, the aux data
column indicates which timer has just expired. For more information, refer
to the Avaya ISDN-BRI Specification.
The switch sent a message to an endpoint that did not respond in the
allotted time. This may be due to failure of the point-to-point signaling link
or because of a problem in the ASAI adjunct. To repair:
■ Execute the test station extension command and perform the
associated repair procedures for those tests.
2568 (i) 0 None
3329 (j) Any Signaling Link
Status (626)
MAJ/WNG
†
OFF
3584-
3839 (k)
0, 1 None
3841 (l)
4095
0None
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2 Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
Aux Data Timer Type
2 First T303 (SETUP timer)
3 Second T303 (SETUP timer)
4 T305 (DISConnect timer)
5 First T308 (RELease timer)
6 Second T308 (RELease timer)
10 T316 (RESTart timer)
12 T309 (Layer 2 Failure timer)
16 TM100 (Management Information Message timer 1)
17 TM200 (Management Information Message timer 2)
102 TASAI (ASAI Routing Timer)
Table 10-56. ASAI-EPT Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
ASAI-EPT
On/
Off
Board Test to Clear Value
Continued on next page