EasyManuals Logo

Cisco MDS 9000 Series Command Reference

Cisco MDS 9000 Series
1464 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1225 background imageLoading...
Page #1225 background image
Send documentation comments to mdsfeedback-doc@cisco.com
22-251
Cisco MDS 9000 Family Command Reference
OL-8413-07, Cisco MDS SAN-OS Release 3.x
Chapter 22 Show Commands
show npv internal info
Statistics:
flogi retry count : 113
ns registration retry count : 0
number of flogis accepted: 0
login failures out of ids: 0
other login failures : 0
timed out login_failures : 0
pending queue size : 0
FLOGIs on this interface :
Interface Information:
ifindex: fc1/5, VSAN: 1, internal FLOGI fcid: 0x000000
FSM current state: NPIVP_EXT_IF_ST_PREINIT_DONE
fabric pwwn: 00:00:00:00:00:00:00:00, fabric nwwn: 00:00:00:00:00:00:00:00
my pwwn: 00:00:00:00:00:00:00:00, my nwwn: 00:00:00:00:00:00:00:00
Port Parameters:
Rx B2B Credits: 0, Multiplier: 0, Buff Size: 0
Tx B2B Credits: 0, Multiplier: 0, Buff Size: 0, bbscn: 0
bbscn_capable: FALSE bbscn_max: 0, port_bbscn: 0
Timer & Retry Information:
Busy Timer (1), id: 00, active: FALSE time remaining: 0
Fail Retry Timer (7), id: 00, active: FALSE time remaining: 0
FDISC Response Timer (2), id: 00, active: FALSE time remaining: 0
Error Clear Timer (6), id: 71, active: TRUE time remaining: 433
Statistics:
flogi retry count : 0
ns registration retry count : 0
number of flogis accepted: 0
login failures out of ids: 0
other login failures : 0
timed out login_failures : 0
pending queue size : 0
FLOGIs on this interface :
Server Interface Info:
======================
Interface Information:
ifindex: fc1/4, VSAN: 1, NPIV enable: FALSE, lcp init done: FALSE
Selected External Interface:
FSM current state: NPIVP_SVR_IF_ST_WAITING_EXTERNAL_INTERFACE
Port Parameters:
rxbbcredit: 0 rxbufsize: 0
txbbcredit: 0 txbufsize: 0 txbbscn: 0
bbscn_capable: FALSE bbscn_max: 0, port_bbscn: 0
Statistics:
number of FLOGIs: 0
Related Commands Command Description
debug npv Enables debugging NPV configurations.
show debug npv Displays the NPV debug commands configured on the switch.

Table of Contents

Other manuals for Cisco MDS 9000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco MDS 9000 Series and is the answer not in the manual?

Cisco MDS 9000 Series Specifications

General IconGeneral
CategorySwitch
Operating SystemCisco NX-OS
PortsVaries by model
ProtocolsFibre Channel (FC), Fibre Channel over IP (FCIP), iSCSI
RedundancyRedundant supervisors, power supplies, and fans
ManagementCisco Data Center Network Manager (DCNM), CLI, SNMP
Virtualization SupportVSANs (Virtual SANs)
Security FeaturesFibre Channel Security Protocol (FC-SP)
Hot Swappable Componentspower supplies, fans
Power Supply OptionsAC and DC options available

Related product manuals