interface fc
interface fc
To configure a Fibre Channel interface on the Cisco MDS 9000 Family of switches, use the interface fc
command in EXEC mode. To revert to defaults, use the no form of the command.
interface fc slot/port
channel-group {group-id [force] | auto}
fcdomain rcf-reject vsan vsan-id
fspf {cost link-cost vsan vsan-id | ficon portnumber portnumber | dead-interval seconds vsan
vsan-id | hello-interval seconds vsan vsan-id | passive vsan vsan-id | retransmit-interval
seconds vsan vsan-id}
interface fc slot/port
no channel-group {group-id [force] | auto}
no fcdomain rcf-reject vsan vsan-id
no fspf {cost link_cost vsan vsan-id | ficon portnumber portnumber | dead-interval seconds
vsan vsan-id | hello-interval seconds vsan vsan-id | passive vsan vsan-id | retransmit-interval
seconds vsan vsan-id}
Syntax Description
Defaults Disabled.
Command Modes Configuration mode.
slot/port Specifies a slot number and port number.
channel-group Adds to or removes from a Port Channel.
group-id Specifies a Port Channel group number from 1 to 128.
force Forcefully adds a port.
auto Enables autocreation of port channels.
fcdomain Enters the interface submode.
rcf-reject Configures the rcf-reject flag.
vsan vsan-id Specifies the VSAN ID. The range is 1 to 4093.
fspf Configures FSPF parameters.
cost link-cost Configures FSPF link cost. The range is 1 to 65535.
dead-interval seconds Configures FSPF dead interval in seconds. The range is 2 to 65535.
ficon Configures FICON parameters.
portnumber portnumber Configures the FICON port number for this interface.
hello-interval seconds Configures FSPF hello-interval. The range is 1 to 65535.
passive Enables or disables FSPF on the interface.
retransmit-interval
seconds
Configures FSPF retransmit interface in seconds. The range is 1 to 65535.

Table of Contents

Other manuals for Cisco MDS 9000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco MDS 9000 Series and is the answer not in the manual?

Cisco MDS 9000 Series Specifications

General IconGeneral
CategorySwitch
Operating SystemCisco NX-OS
PortsVaries by model
ProtocolsFibre Channel (FC), Fibre Channel over IP (FCIP), iSCSI
RedundancyRedundant supervisors, power supplies, and fans
ManagementCisco Data Center Network Manager (DCNM), CLI, SNMP
Virtualization SupportVSANs (Virtual SANs)
Security FeaturesFibre Channel Security Protocol (FC-SP)
Hot Swappable Componentspower supplies, fans
Power Supply OptionsAC and DC options available

Related product manuals