Send documentation comments to mdsfeedback-doc@cisco.com
21-84
Cisco MDS 9000 Family Command Reference
OL-8413-07, Cisco MDS SAN-OS Release 3.x
Chapter 21 S Commands
system health (Configuration mode)
system health (Configuration mode)
To configure Online Health Management System (OHMS) features for a specified interface or for the
entire switch, use the system health command. To disable this feature, use the no form of the command.
system health [failure-action | interface {fc slot/port | iscsi slot/port} |
loopback {frame-length {bytes | auto} | frequency seconds}]
no system health [failure-action | interface {fc slot/port | iscsi slot/port}]
Note On a Cisco Fabric Switch for HP c-Class BladeSystem and on a Cisco Fabric Switch for IBM
BladeCenter, the syntax differs as follows:
interface {bay port | ext port}
Syntax Description
Defaults Enabled.
Frame-length is auto-size, which could range from 0 to 128.
Command Modes Configuration mode.
Command History
failure-action Prevents the SAN-OS software from taking any OHMS action for the
entire switch.
interface Configures an interface.
fc slot/port (Optional) Specifies the Fibre Channel interface to configure by slot and
port number on an MDS 9000 Family switch.
iscsi slot/port (Optional) Specifies the iSCSI interface to configure by slot and port
number on an MDS 9000 Family switch.
bay port | ext port (Optional) Configures the Fibre Channel interface on a port on a Cisco
Fabric Switch for HP c-Class BladeSystem or on a Cisco Fabric Switch
for IBM BladeCenter. The range is 0 to 48.
loopback Configures the OHMS loopback test.
frame-length bytes Specifies the frame-length in bytes ranging from 0 to 128 bytes for the
loopback test.
auto Configures the frame-length to auto for the loopback test.
frequency seconds Specifies the loopback frequency in seconds ranging from 5 seconds
(default) to 255 seconds.
Release Modification
1.3(4) This command was introduced.
3.0(1) Added the frame-length and auto options to the loopback keyword.
3.1(2) Added the interface bay | ext option.

Table of Contents

Other manuals for Cisco MDS 9000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco MDS 9000 Series and is the answer not in the manual?

Cisco MDS 9000 Series Specifications

General IconGeneral
CategorySwitch
Operating SystemCisco NX-OS
PortsVaries by model
ProtocolsFibre Channel (FC), Fibre Channel over IP (FCIP), iSCSI
RedundancyRedundant supervisors, power supplies, and fans
ManagementCisco Data Center Network Manager (DCNM), CLI, SNMP
Virtualization SupportVSANs (Virtual SANs)
Security FeaturesFibre Channel Security Protocol (FC-SP)
Hot Swappable Componentspower supplies, fans
Power Supply OptionsAC and DC options available

Related product manuals