EasyManuals Logo

Cisco MDS 9000 Series Command Reference

Cisco MDS 9000 Series
1464 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #578 background imageLoading...
Page #578 background image
Send documentation comments to mdsfeedback-doc@cisco.com
11-20
Cisco MDS 9000 Family Command Reference
OL-8413-07, Cisco MDS SAN-OS Release 3.x
Chapter 11 I Commands
interface
interface
To configure an interface on the Cisco MDS 9000 Family of switches, use the interface command in
configuration mode.
interface {cpp | fc | fc-tunnel | fcip | gigabitethernet | iscsi | mgmt | port-channel | svc | vsan}
Note On a Cisco Fabric Switch for HP c-Class BladeSystem and on a Cisco Fabric Switch for IBM
BladeCenter, the syntax differs as follows:
interface {bay port | ext port}
Syntax Description
Defaults Disabled.
Command Modes Configuration mode.
Command History
bay port | ext port (Optional) Configures a a Fibre Channel interface on a port on a Cisco Fabric
Switch for HP c-Class BladeSystem or on a Cisco Fabric Switch for IBM
BladeCenter. The range is 0 to 48.
cpp Configures a Control Plane Process (CPP) interface.
fc (Optional) Configures a Fiber Channel interface on an MDS 9000 Family
switch—see the interface fc command.
fc-tunnel Configures a Fiber Channel link interface—see the interface fc-tunnel
command.
fcip Configures a Fibre Channel over IP (FCIP) interface—see the interface fcip
command.
gigabitethernet Configures a Gigabit Ethernet interface—see the interface gigabitethernet
command.
iscsi Configures an iSCSI interface—see the interface iscsi command.
mgmt Configures a management interface—see the interface mgmt command.
port-channel Configures a PortChannel interface—see the interface port-channel
command.
svc Configures a SAN Volume Controller (SVC) interface for the Caching
Services Module (CSM)—see the interface svc command.
vsan Configures a VSAN interface—see the interface vsan command.
Release Modification
1.0(2) This command was introduced.
3.1(2) Added the bay | port option.

Table of Contents

Other manuals for Cisco MDS 9000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco MDS 9000 Series and is the answer not in the manual?

Cisco MDS 9000 Series Specifications

General IconGeneral
CategorySwitch
Operating SystemCisco NX-OS
PortsVaries by model
ProtocolsFibre Channel (FC), Fibre Channel over IP (FCIP), iSCSI
RedundancyRedundant supervisors, power supplies, and fans
ManagementCisco Data Center Network Manager (DCNM), CLI, SNMP
Virtualization SupportVSANs (Virtual SANs)
Security FeaturesFibre Channel Security Protocol (FC-SP)
Hot Swappable Componentspower supplies, fans
Power Supply OptionsAC and DC options available

Related product manuals