system health module
system health module
To configure Online Health Management System (OHMS) features for a specified module, use the
system health module command. To disable these features, use the no form of this command.
system health module slot
[battery-charger [failure-action | frequency seconds] |
bootflash [failure-action | frequency seconds] |
cache-disk [failure-action | frequency seconds] |
cf-crc-check [failure-action | frequency frequency] |
cf-re-flash [failure-action | frequency frequency] |
eobc [failure-action | frequency seconds] |
failure-action |
inband [failure-action | frequency seconds] |
loopback [failure-action] |
mgmt [failure-action | frequency seconds]]
no system health module slot
[battery-charger [failure-action | frequency seconds] |
bootflash [failure-action | frequency seconds] |
cache-disk [failure-action | frequency seconds] |
cf-crc-check [
failure-action | frequency frequency] |
cf-re-flash [failure-action | frequency frequency] |
eobc [failure-action | frequency seconds] |
failure-action |
inband [failure-action | frequency seconds] |
loopback [failure-action] |
mgmt [failure-action | frequency seconds]]
Syntax Description module slot Specifies the module slot number.
battery-charger Configures the battery-charger test on the specified module.
frequency seconds Specifies the frequency in seconds. The range for the bootflash
frequency option is 10 to 255. The range for the cf-crc-check frequency
option is 1 to 30. The range for the cf-re-flash frequency option is 30 to
90. For all other options, the range is 5 to 255.
failure-action Controls the software from taking any action if a CompactFlash failure is
determined while running the CRC checksum test.
bootflash Configures the bootflash test on the specified module.
cache-disk Configures the cache-disk test on the specified module.
cf-crc-check Configures the CRC checksum test.
cf-re-flash Configures the firmware update.
eobc Configures the EOBC test on the specified module.
inband Configures the inband test on the specified module.
loopback Configures the loopback test on the specified module.
mgmt Configures the management port test on the specified module.

Table of Contents

Other manuals for Cisco MDS 9000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco MDS 9000 Series and is the answer not in the manual?

Cisco MDS 9000 Series Specifications

General IconGeneral
CategorySwitch
Operating SystemCisco NX-OS
PortsVaries by model
ProtocolsFibre Channel (FC), Fibre Channel over IP (FCIP), iSCSI
RedundancyRedundant supervisors, power supplies, and fans
ManagementCisco Data Center Network Manager (DCNM), CLI, SNMP
Virtualization SupportVSANs (Virtual SANs)
Security FeaturesFibre Channel Security Protocol (FC-SP)
Hot Swappable Componentspower supplies, fans