Send documentation comments to mdsfeedback-doc@cisco.com
21-42
Cisco MDS 9000 Family Command Reference
OL-8413-07, Cisco MDS SAN-OS Release 3.x
Chapter 21 S Commands
source
source
To configure a switched port analyzer (SPAN) source, use the source command in SPAN session
configuration submode. To disable this feature, use the no form of the command.
source {
filter vsan vsan-id |
interface {
fc slot/port [rx [traffic-type {initiator | mgmt | target}] | tx [traffic-type {initiator | mgmt |
target}] | traffic-type {initiator | mgmt | target}] |
fcip fcip-id |
fv slot/dpp-number/fv-port |
iscsi slot/port [rx [traffic-type {initiator | mgmt | target}] | tx [traffic-type {initiator | mgmt
| target}] | traffic-type {initiator | mgmt | target}]|
port-channel channel-number [rx [traffic-type {initiator | mgmt
| target}] | tx [traffic-type
{initiator | mgmt | target}] | traffic-type {initiator | mgmt | target}] |
sup-fc number [rx [traffic-type {initiator | mgmt | target}] | tx [traffic-type {initiator |
mgmt | target}] | traffic-type {initiator | mgmt | target}]} |
vsan vsan-id}
no source {
filter vsan vsan-id |
interface {
fc slot/port [rx [traffic-type {initiator | mgmt | target}] | tx [traffic-type {initiator | mgmt |
target}] | traffic-type {initiator | mgmt | target}] |
fcip
fcip-id |
fv slot/dpp-number/fv-port |
iscsi slot/port [rx [traffic-type {initiator | mgmt | target}] | tx [traffic-type {initiator | mgmt
| target}] | traffic-type {initiator | mgmt | target}]|
port-channel channel-number [rx [traffic-type {initiator | mgmt | target}] | tx [traffic-type
{initiator | mgmt | target}] | traffic-type {initiator | mgmt | target}] |
sup-fc number [rx [traffic-type {initiator | mgmt | target}] | tx [traffic-type {initiator |
mgmt | target}] | traffic-type {initiator
| mgmt | target}]} |
vsan vsan-id}
Note On a Cisco Fabric Switch for HP c-Class BladeSystem and on a Cisco Fabric Switch for IBM
BladeCenter, the syntax differs as follows:
interface {bay port | ext port}
Syntax Description filter Configures SPAN session filter.
vsan vsan-id Specifies the VSAN ID. The range is 1 to 4093.
interface Specifies the interface type.
fc slot/port (Optional) Specifies the Fibre Channel interface ID at a slot and port on an
MDS 9000 Family switch.
fcip fcip-id Specifies the FCIP interface ID. The range is 1 to 255.
fv
slot/dpp-number/fv-port
Specifies a virtual F port (FV port) interface in the specified slot along with
the data path processor (DPP) number and the FV port number.