fspf cost
fspf cost
To configure FSPF link cost for an FCIP interface, use the fspf cost command. To revert to the default
value, use the no form of the command.
fspf cost link-cost vsan vsan-id
no fspf cost link-cost vsan vsan-id
Syntax Description
Defaults 1000 seconds for 1 Gbps
500 seconds for 2 Gbps
Command Modes Interface configuration submode.
Command History
Usage Guidelines Access this command from the
switch(config-if)# submode.
FSPF tracks the state of links on all switches in the fabric, associates a cost with each link in its database,
and then chooses the path with a minimal cost. The cost associated with an interface can be changed
using the fspf cost command to implement the FSPF route selection.
Examples The following example configures the FSPF link cost on an FCIP interface.
switch# config terminal
switch(config)# interface fcip 1
switch(config-if)# fspf cost 5000 vsan 1
Related Commands
link-cost Enters FSPF link cost in seconds. The range is 1 to 65535.
vsan vsan-id Specifies a VSAN ID. The range is 1 to 4093.
Release Modification
1.1(1) This command was introduced.
Command Description
show fspf interface Displays information for each selected interface.
show interface fcip Displays an interface configuration for a specified FCIP interface.

Table of Contents

Other manuals for Cisco MDS 9000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco MDS 9000 Series and is the answer not in the manual?

Cisco MDS 9000 Series Specifications

General IconGeneral
CategorySwitch
Operating SystemCisco NX-OS
PortsVaries by model
ProtocolsFibre Channel (FC), Fibre Channel over IP (FCIP), iSCSI
RedundancyRedundant supervisors, power supplies, and fans
ManagementCisco Data Center Network Manager (DCNM), CLI, SNMP
Virtualization SupportVSANs (Virtual SANs)
Security FeaturesFibre Channel Security Protocol (FC-SP)
Hot Swappable Componentspower supplies, fans
Power Supply OptionsAC and DC options available

Related product manuals