target (iSLB initiator configuration)
target (iSLB initiator configuration)
To configure an iSLB initiator target, use the target command in iSLB initiator configuration submode.
To remove the target configuration, use the no form of the command.
target {device-alias device-alias | pwwn pWWN}
[vsan vsan-id]
[no-zone]
[trespass]
[revert-primary-port]
[fc-lun LUN iscsi-lun LUN]
[sec-device-alias device-alias | sec-pwwn pWWN]
[sec-vsan sec-vsan-id]
[sec-lun LUN]
[iqn-name target-name]
no target {device-alias device-alias | pwwn pWWN}
[vsan vsan-id]
[no-zone]
[trespass]
[revert-primary-port]
[fc-lun LUN iscsi-lun LUN]
[sec-device-alias device-alias | sec-pwwn pWWN]
[sec-vsan sec-vsan-id]
[sec-lun LUN]
[iqn-name target-name]
Syntax Description device-alias
device-alias
Specifies the device alias of the Fibre Channel target.
pwwn pWWN Specifies the pWWN of the Fibre Channel target. The format is
hh:hh:hh:hh:hh:hh:hh:hh.
vsan Assigns VSAN membership to the initiator target.
vsan-id Specifies the VSAN ID. The range is 1 to 4093.
no-zone Indicates no automatic zoning.
trespass Enables trespass support.
revert-primary-port Reverts to the primary port when it comes back up.
fc-lun LUN Specifies the Fibre Channel LUN of the Fibre Channel target. The format is
0xhhhh[:hhhh[:hhhh[:hhhh]]]
iscsi-lun LUN Specifies the iSCSI LUN. The format is 0xhhhh[:hhhh[:hhhh[:hhhh]]].
sec-device-alias
Specifies the device alias of the secondary Fibre Channel target.
target-device-alias Specifies the initiator’s target device alias. The maximum size is 64.
sec-pwwn pWWN Specifies the pWWN of the secondary Fibre Channel target. The format is
hh:hh:hh:hh:hh:hh:hh:hh.
sec-vsan Assigns VSAN membership to the initiator.
sec-vsan-id Specifies the VSAN ID. The range is 1 to 4093.
sec-lun LUN Specifies the FC LUN of the secondary Fibre Channel target. The format is
0xhhhh[:hhhh[:hhhh[:hhhh]]].

Table of Contents

Other manuals for Cisco MDS 9000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco MDS 9000 Series and is the answer not in the manual?

Cisco MDS 9000 Series Specifications

General IconGeneral
CategorySwitch
Operating SystemCisco NX-OS
PortsVaries by model
ProtocolsFibre Channel (FC), Fibre Channel over IP (FCIP), iSCSI
RedundancyRedundant supervisors, power supplies, and fans
ManagementCisco Data Center Network Manager (DCNM), CLI, SNMP
Virtualization SupportVSANs (Virtual SANs)
Security FeaturesFibre Channel Security Protocol (FC-SP)
Hot Swappable Componentspower supplies, fans
Power Supply OptionsAC and DC options available

Related product manuals