WARNING 610: No interface card.
Insert the interface card (PC card).
WARNING 620: Cannot connect. (LAN)
Check the settings or connection environment.
WARNING 622: LAN: Bad IP adress.
The IP address is not set correctly.
WARNING 623: LAN: Bad server IP
address.
The IP of the server (that runs the 9333) is not specified
correctly.
WARNING 624: LAN: Can not connect to
server.
The 8841/42 cannot connect to the PC that runs the 9333.
Check the connection environment.
WARNING 625: LAN: Can not connect to
9333.
The 8841/42 cannot connect to the 9333. Check on the PC to
see whether the 9333 is in standby status.
WARNING 626: LAN: Connection time
out.
Check the connection environment.
WARNING 627: LAN: Transfer was
aborted.
Data transmission is interrupted by the STOP key or from the
9333.
WARNING 628: LAN: Network error.
Check the connection environment.
WARNING 629: LAN: Server not found or
DNS failed.
Check whether the DNS server is running or set up correctly.
WARNING 630: LAN: DHCP failed.
Check whether the DHCP server is running correctly on the
network.
WARNING 797: Mem shot changed.
Since the recording length is long, the recording length will
also be short.
WARNING 798: Invalid. (time/div:20ms-
200ms)
Since the time axis range is set to 20 to 200 ms/division by
the recorder and memory function, the printer cannot be
turned on.
WARNING 799: Invalid. (shot:CONT.)
Since the time axis range is set to 20 to 200 ms/division by
the recorder, and memory function and recording length are
set to "CONT.," the printer cannot be turned on.