E-DIG-STA (Emulated Digital Line)
Issue 4 May 2002
10-729555-233-123
1002 ABORT The system could not allocate time slots for the test. The
system is under heavy traffic conditions or it has time slots
out-of-service due to TDM-BUS errors. Refer to TDM-BUS to
diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling
heavy traffic, repeat test at 1-minute intervals a maximum
of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The
system is oversized for the number of Tone Detectors present,
or some Tone Detectors are out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer
to TTR-LEV documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer
to TONE-PT documentation.
3. If neither condition exists, retry the command at 1-minute
intervals a maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has
been aborted. Use the display port PCSSpp command to
determine the station extension or attendant number of the
port. Use status station or status attendant to determine the
service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. Wait
until the port is idle before retesting. Attendants are always in
use (off-hook) if the handset is plugged in and the port is not
busied out.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort and the port is not in use,
escalate the problem.
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this
test.
1. Rerun the test at 1-minute intervals a maximum of 5 times.
Table 10-272. TEST #13 Voice and Control Channel Local Loop Test — Continued
Error
Code
Te s t
Result Description/Recommendation