Maintenance Object Repair Procedures
555-233-123
10-730 Issue 4 May 2002
7 FAIL Conference Test failed on primary channel. In some cases,
users may not notice disruption in service. In extreme cases,
conferencing feature may not work at all.
14 FAIL The primary voice channel is not transmitting properly. User
impact may range from noticing nothing to not being able to
use this port.
15 FAIL The control channel between the processor and digital circuit
pack is not transmitting properly. User impact may range from
noticing nothing to not being able to use the port. This could
disrupt other users.
16 FAIL The secondary voice channel is not transmitting properly. User
impact may range from noticing nothing to not being able to
use this port.
1. Run circuit pack tests to check the Tone Generator circuit
pack and the Tone Detector circuit pack using the test
board PCSSpp command.
2. Resolve any problems that are detected on the Tone
Generator circuit pack or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit packs are
functioning properly and the test still fails, replace the
Digital Line circuit pack.
PASS The test passed, and all channels are transmitting properly.
1. To ensure that this is not an intermittent problem, repeat
this test up to 10 times.
2. If noisy connections for voice or corrupted data for data
transfer persist, examine the station, connections, and
wiring.
Table 10-272. TEST #13 Voice and Control Channel Local Loop Test — Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page