Page #1104 background image
Send documentation comments to mdsfeedback-doc@cisco.com
22-130
Cisco MDS 9000 Family Command Reference
OL-8413-07, Cisco MDS SAN-OS Release 3.x
Chapter 22 Show Commands
show interface
Examples The following example shows how to display information about a Fibre Channel interface.
switch# show interface fc1/11
fc1/11 is up
Hardware is Fibre Channel
Port WWN is 20:0b:00:05:30:00:59:de
Admin port mode is ST
Port mode is ST
Port vsan is 1
Speed is 1 Gbps
Rspan tunnel is fc-tunnel 100
Beacon is turned off
5 minutes input rate 248 bits/sec, 31 bytes/sec, 0 frames/sec
5 minutes output rate 176 bits/sec, 22 bytes/sec, 0 frames/sec
6862 frames input, 444232 bytes
0 discards, 0 errors
0 CRC, 0 unknown class
0 too long, 0 too short
6862 frames output, 307072 bytes
Table 22-5 Interface Types for the show interface Command
Interface Type Description
bay port | ext port Displays information for a Fibre Channel interface on a Cisco Fabric
Switch for HP c-Class BladeSystem or a Cisco Fabric Switch for IBM
BladeCenter.
cpp slot/port Displays information for a virtualization interface.
fc slot/port Displays the Fibre Channel interface in the specified slot/port.
fc-tunnel tunnel-id Displays description of the specified FC tunnel from 1 to 4095.
fcip interface-number Specifies a FCIP interface. The range is 1 to 255.
fv slot/dpp-number/fv-port Displays information for the virtual F port (FV port) interface in the
specified slot along with the data path processor (DPP) number and the
FV port number.
gigabitethernet slot/port Displays information for a Gigabit Ethernet interface at the specified slot
and port.
gigabitethernet slot/port.
subinterface-number
Displays information for a Gigabit Ethernet subinterface at the specified
slot and port followed by a dot (.) indicator and the subinterface number.
The subinterface range is 1 to 4093.
iscsi slot/port Displays the description of the iSCSI interface in the specified slot and
port.
mgmt 0 Displays the description of the management interface.
port-channel
port-channel-number
Displays the PortChannel interface specified by the PortChannel number.
The range is 1 to 128.
port-channel
port-channel-number
.subinterface-number
Displays the PortChannel subinterface specified by the PortChannel
number followed by a dot (.) indicator and the subinterface number. The
port channel number range is 1 to 128. The subinterface range is 1 to
4093.
sup-fc 0 Displays the in-band interface details.
vsan vsan-id Displays information for a VSAN. The range is 1 to 4093.

Table of Contents

Other manuals for Cisco MDS 9000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco MDS 9000 Series and is the answer not in the manual?

Cisco MDS 9000 Series Specifications

General IconGeneral
CategorySwitch
Operating SystemCisco NX-OS
PortsVaries by model
ProtocolsFibre Channel (FC), Fibre Channel over IP (FCIP), iSCSI
RedundancyRedundant supervisors, power supplies, and fans
ManagementCisco Data Center Network Manager (DCNM), CLI, SNMP
Virtualization SupportVSANs (Virtual SANs)
Security FeaturesFibre Channel Security Protocol (FC-SP)
Hot Swappable Componentspower supplies, fans
Power Supply OptionsAC and DC options available