Send documentation comments to mdsfeedback-doc@cisco.com
22-135
Cisco MDS 9000 Family Command Reference
OL-8413-07, Cisco MDS SAN-OS Release 3.x
Chapter 22 Show Commands
show interface
5 minutes output rate 375002168 bits/sec, 46875271 bytes/sec, 33833 frames/sec
iSCSI statistics
6202235 packets input, 299732864 bytes
Command 6189718 pdus, Data-out 1937 pdus, 1983488 bytes, 0 fragments
146738794 packets output, 196613551108 bytes
Response 6184282 pdus (with sense 4), R2T 547 pdus
Data-in 140543388 pdus, 189570075420 bytes
The following example shows how to display transceiver information for a Fibre Channel interface.
switch# show interface fc2/5 transceiver
fc2/5 fcot is present
name is CISCO-INFINEON
part number is V23848-M305-C56C
revision is A3
serial number is 30000474
fc-transmitter type is short wave laser
cisco extended id is unknown (0x0)
The following example shows how to display information about a Fibre Channel tunnel interface.
switch# show interface fc-tunnel 200
fc-tunnel 200 is up
Dest IP Addr: 200.200.200.7 Tunnel ID: 200
Source IP Addr: 200.200.200.4 LSP ID: 1
Explicit Path Name:
The following example shows how to display hardware port information for a Fibre Channel interface.
switch# show interface fc1/24 capabilities
Min Speed is 1 Gbps
Max Speed is 4 Gbps
FC-PH Version (high, low) (0,6)
Receive data field size (max/min) (2112/256) bytes
Transmit data field size (max/min) (2112/128) bytes
Classes of Service supported are Class 2, Class 3, Class F
Class 2 sequential delivery supported
Class 3 sequential delivery supported
Hold time (max/min) (100/1) micro sec
BB state change notification supported
Maximum BB state change notifications 14
Rate Mode change supported
Rate Mode Capabilities Shared Dedicated
Receive BB Credit modification supported yes yes
FX mode Receive BB Credit (min/max/default) (0/0/0) (1/60/16)
ISL mode Receive BB Credit (min/max/default) -- (2/60/16)
Performace buffer modification supported no no
Out of Service capable yes
Beacon mode configurable yes
The following example shows how to display information about a Fibre Channel interface on a Cisco
Fabric Switch for HP c-Class BladeSystem.
switch# show interface bay 11
bay11 is down (Externally Disabled)
Hardware is Fibre Channel
Port WWN is 20:0c:00:05:30:01:f9:f2
Admin port mode is auto, trunk mode is on
snmp link state traps are enabled
Port vsan is 1