Cisco MDS 9000 Family Command Reference
OL-8413-07, Cisco MDS SAN-OS Release 3.x
Chapter 22 Show Commands
show interface
2 Active TCP connections
Control connection: Local 43.1.1.2:3225, Remote 43.1.1.1:65532
Data connection: Local 43.1.1.2:3225, Remote 43.1.1.1:65534
30 Attempts for active connections, 0 close of connections
TCP Parameters
Path MTU 1500 bytes
Current retransmission timeout is 300 ms
Round trip time: Smoothed 10 ms, Variance: 5
Advertised window: Current: 122 KB, Maximum: 122 KB, Scale: 1
Peer receive window: Current: 114 KB, Maximum: 114 KB, Scale: 1
Congestion window: Current: 2 KB, Slow start threshold: 1048560 KB
5 minutes input rate 64 bits/sec, 8 bytes/sec, 0 frames/sec
5 minutes output rate 64 bits/sec, 8 bytes/sec, 0 frames/sec
866 frames input, 80604 bytes
866 Class F frames input, 80604 bytes
0 Class 2/3 frames input, 0 bytes
0 Error frames timestamp error 0
864 frames output, 80048 bytes
864 Class F frames output, 80048 bytes
0 Class 2/3 frames output, 0 bytes
0 Error frames 0 reass frames
16 receive B2B credit remaining
3 transmit B2B credit remaining.
The following example shows how to display information about a Gigabit Ethernet interface.
switch# show interface gigabitethernet 4/1
GigabitEthernet4/1 is up
Hardware is GigabitEthernet, address is 0005.3000.2e12
Internet address is 100.1.1.2/24
MTU 1500 bytes, BW 1000000 Kbit
Port mode is IPS
Speed is 1 Gbps
Beacon is turned off
5 minutes input rate 32 bits/sec, 4 bytes/sec, 0 frames/sec
5 minutes output rate 88 bits/sec, 11 bytes/sec, 0 frames/sec
637 packets input, 49950 bytes
0 multicast frames, 0 compressed
0 input errors, 0 frame, 0 overrun 0 fifo
659 packets output, 101474 bytes, 0 underruns
0 output errors, 0 collisions, 0 fifo
0 carrier errors
The following example shows how to display information about an iSCSI interface.
switch# show interface iscsi 2/1
iscsi2/1 is up
Hardware is GigabitEthernet
Port WWN is 20:41:00:05:30:00:50:de
Admin port mode is ISCSI
Port mode is ISCSI
Speed is 1 Gbps
iSCSI initiator is identified by name
Number of iSCSI session: 7, Number of TCP connection: 7
Configured TCP parameters
Local Port is 3260
PMTU discover is disabled
Keepalive-timeout is 1 sec
Minimum-retransmit-time is 300 ms
Max-retransmissions 8
Sack is disabled
Minimum available bandwidth is 0 kbps
Estimated round trip time is 0 usec
5 minutes input rate 265184 bits/sec, 33148 bytes/sec, 690 frames/sec

Table of Contents

Other manuals for Cisco MDS 9000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco MDS 9000 Series and is the answer not in the manual?

Cisco MDS 9000 Series Specifications

General IconGeneral
CategorySwitch
Operating SystemCisco NX-OS
PortsVaries by model
ProtocolsFibre Channel (FC), Fibre Channel over IP (FCIP), iSCSI
RedundancyRedundant supervisors, power supplies, and fans
ManagementCisco Data Center Network Manager (DCNM), CLI, SNMP
Virtualization SupportVSANs (Virtual SANs)
Security FeaturesFibre Channel Security Protocol (FC-SP)
Hot Swappable Componentspower supplies, fans
Power Supply OptionsAC and DC options available

Related product manuals