Page #1174 background imageLoading...
Page #1174 background image
Send documentation comments to mdsfeedback-doc@cisco.com
22-200
Cisco MDS 9000 Family Command Reference
OL-8413-07, Cisco MDS SAN-OS Release 3.x
Chapter 22 Show Commands
show ivr
The following example displays the configured IVR VSAN topology.
switch# show ivr vsan-topology configured
AFID SWITCH WWN Active Cfg. VSANS
--------------------------------------------------------------
1 20:00:00:05:30:00:3c:5e yes yes 3,2000
1 20:00:00:05:30:00:58:de yes yes 2,2000
1 20:00:00:05:30:01:1b:c2 * yes yes 1-2
1 20:02:00:44:22:00:4a:05 yes yes 1-2,6
1 20:02:00:44:22:00:4a:07 yes yes 2-5
Total: 5 entries in configured IVR VSAN-Topology
The following example displays the combined user-defined and the automatically discovered IVR VSAN
topology database.
switch(config)# show ivr vsan-topology
AFID SWITCH WWN Active Cfg. VSANS
--------------------------------------------------------------
1 20:00:00:0d:ec:04:99:00 yes no 1-4
1 20:00:00:0d:ec:0e:9c:80 * yes no 2,6-7,9
1 20:00:00:0d:ec:0e:b0:40 yes no 1-3,5,8
1 20:00:00:0d:ec:04:99:00 no yes 1-4
1 20:00:00:0d:ec:0e:9c:80 * no yes 2,6-7,9
1 20:00:00:0d:ec:0e:b0:40 no yes 1-3,5,8
Total: 6 entries in active and configured IVR VSAN-Topology
Table 22-6 describes the significant fields shown in the show ivr vsan-topology display.
The following example displays the IVZ configuration.
switch# show ivr zone
zone name Ivz_vsan2-3
pwwn 21:00:00:e0:8b:02:ca:4a vsan 3
pwwn 21:00:00:20:37:c8:5c:6b vsan 2
zone name ivr_qa_z_all
pwwn 21:00:00:e0:8b:06:d9:1d vsan 1
pwwn 21:01:00:e0:8b:2e:80:93 vsan 4
pwwn 10:00:00:00:c9:2d:5a:dd vsan 1
pwwn 10:00:00:00:c9:2d:5a:de vsan 2
pwwn 21:00:00:20:37:5b:ce:af vsan 6
pwwn 21:00:00:20:37:39:6b:dd vsan 6
pwwn 22:00:00:20:37:39:6b:dd vsan 3
pwwn 22:00:00:20:37:5b:ce:af vsan 3
pwwn 50:06:04:82:bc:01:c3:84 vsan 5
Table 22-6 show ivr vsan-topology Field Descriptions
Field Description
AFID Autonomous fabric ID (AFID)
Switch WWN Switch world wide number
Active Automatically discovered
Cfg. Manually configured
VSANS VSANs configured

Table of Contents

Other manuals for Cisco MDS 9000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco MDS 9000 Series and is the answer not in the manual?

Cisco MDS 9000 Series Specifications

General IconGeneral
CategorySwitch
Operating SystemCisco NX-OS
PortsVaries by model
ProtocolsFibre Channel (FC), Fibre Channel over IP (FCIP), iSCSI
RedundancyRedundant supervisors, power supplies, and fans
ManagementCisco Data Center Network Manager (DCNM), CLI, SNMP
Virtualization SupportVSANs (Virtual SANs)
Security FeaturesFibre Channel Security Protocol (FC-SP)
Hot Swappable Componentspower supplies, fans
Power Supply OptionsAC and DC options available

Related product manuals