Command Modes EXEC mode.
Command History
Usage Guidelines The show tech-support command is useful when collecting a large amount of information about your
switch for troubleshooting purposes. The output of this command can be provided to technical support
representatives when reporting a problem.
The show tech-support command displays the output of several show commands at once. The output
from this command varies depending on your configuration. Use the show tech-support command in
EXEC mode to display general information about the switch when reporting a problem.
You can choose to have detailed information for each command or even specify the output for a particular
interface, module, or VSAN.
Examples The following example displays technical support information for a specific module.
switch# show tech-support module 1
'terminal length 0'
'show module '
Mod Ports Module-Type Model Status
--- ----- ------------------------------- ------------------ ------------
1 16 1/2 Gbps FC/Supervisor DS-X9216-K9-SUP active *
2 32 1/2 Gbps FC Module DS-X9032 ok
Mod Sw Hw World-Wide-Name(s) (WWN)
--- ----------- ------ --------------------------------------------------
1 1.0(0.271) 0.0 20:01:00:05:30:00:21:9e to 20:10:00:05:30:00:21:9e
2 1.0(0.271) 0.0 20:41:00:05:30:00:21:9e to 20:60:00:05:30:00:21:9e
Mod MAC-Address(es) Serial-Num
--- -------------------------------------- ----------
1 00-05-30-00-40-b6 to 00-05-30-00-40-ba
2 00-05-30-00-11-22 to 00-05-30-00-11-26
* this terminal session
'show environment'
Clock:
----------------------------------------------------------
Clock Model Hw Status
----------------------------------------------------------
A Clock Module -- ok/active
B Clock Module -- ok/standby
Fan:
------------------------------------------------------
Release Modification
1.3(4) This command was introduced.
3.0(1) Added the fcdomain, port-channel, and zone options.
3.0(3) Added the cfs, fcip, fspf, fta, ip, license, prefpath, and vrrp options.
3.1(1) Added the device-alias keyword.
3.1(2) Added the bay port | ext port keywords and arguments.

Table of Contents

Other manuals for Cisco MDS 9000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco MDS 9000 Series and is the answer not in the manual?

Cisco MDS 9000 Series Specifications

General IconGeneral
CategorySwitch
Operating SystemCisco NX-OS
PortsVaries by model
ProtocolsFibre Channel (FC), Fibre Channel over IP (FCIP), iSCSI
RedundancyRedundant supervisors, power supplies, and fans
ManagementCisco Data Center Network Manager (DCNM), CLI, SNMP
Virtualization SupportVSANs (Virtual SANs)
Security FeaturesFibre Channel Security Protocol (FC-SP)
Hot Swappable Componentspower supplies, fans
Power Supply OptionsAC and DC options available

Related product manuals