EasyManua.ls Logo

Doosan DA40 - Changing the oil

Doosan DA40
945 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SHOP MANUAL
Engine
Ch 1 page 88
Changing the oil
Renew the oil lter and clean the centrifugal oil cleaner when
changing oil.
NOTE
AVOID DEATH OR SERIOUS INJURY
• Hot oil can cause burns and skin irritation. Wear protective
gloves and goggles when changing hot oil.
• Make sure that there is no pressure in the lubrication system
before starting work on it.
• The oil ller cap must always be in place when starting and
running the engine to prevent oil being ejected.
Use a container to avoid spillage. Used oil must be disposed of
as specied in national and international law.
Change oil more often if the engine is subjected to particularly
demanding operation, such as a dusty environment, or if de-
posits in the centrifugal oil cleaner are thicker than 28 mm.
NOTE
NOTE
WARNING
1. Unscrew the oil plug and drain the oil when the engine is
hot. In certain engines the oil is pumped out by means of a
bilge pump.
2. Clean the magnet on the oil plug.
3. Refit the oil plug.
4. Fill up with oil.
5. Check the level on the dipstick.
Maximum angles of inclination during operation.
Maximum permissible angles during operation vary, depending
on the type of oil sump; see figure 169.
30
30
30
25
Max. 45 litres
Min. 34 litres
Max. 34 litres
Min. 28 litres
30
30
30
25
Figure 168
Figure 169
Oil level must not be less than: