The brake chamber is to be pressure tested with 0,4 – 0,5 bar
compressed air for approx. 5 min. No pressure loss is allowed.
(S) Air connection with pressure
gauge and pressure release valve 514660
(S) Reducing tool 514671
Install the screw plugs (1) with new O-Rings.
Tightening torque (M22x1,5) ........................…... MA = 60 Nm
Check the brake chamber/wheel head for leak
tightness
Figure 120