EasyManua.ls Logo

Doosan DA40 - High system voltage; External oil leakage; External fuel leakage

Doosan DA40
945 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SHOP MANUAL
Engine
Ch 1 page 250
High system voltage
External oil leakage
External fuel leakage
Eect Cause Trouble shooting Action
(Normal charging
voltage:
27 - 28 V)
Voltage regulator fault
Battery charger fault
Eect Cause Trouble shooting Action
Crankcase pressure too
high
Check “blow-by” in crankcase
Correct value for new engine: 0 - +10 mm wc
(ow rate 60 - 100 l/min.)
Closed crankcase ventilation: -50 - +20 mm wc
Leaky crankshaft seal
Leakage at liner seal via
overow hole in cylin-
der block
Defective cylinder head
gasket
Leakage in manifold
joint
Low load
Eect Cause Trouble shooting Action
Damaged injector and
injection pump connec-
tions/gaskets
Defective pulsation
damper
Blocked overow valve
Leakage at high engine
speed and low power
output
- Change to Bosch over-
ow valve (with ball)

Table of Contents