SHOP MANUAL
Engine
Ch 1 page 240
Eect Cause Trouble shooting Action
Air in fuel system
Leakage in suction pipe
The highest fuel level in
the tank is lower than the
feed pump. A longer
standstill (days) the fuel
in the suction pipe may
run back to the tank
because of a leaky over-
ow valve
- Install a ”daily supply
tank” at a higher loca-
tion than the feed pump
Leaky overow valve
Low battery voltage
Ambient temperature
too low
- Starting aids are not
normally needed at
temperatures above
-15 ° C
Oil viscosity too high
Paran precipitation in
the fuel
Blocked intake or
exhaust system
No fuel
Stop lever in stop posi-
tion
- Check the stop
solenoid and links
Wrong injection timing
Faulty injector
Control rack/pump ele-
ment will not go into the
cold start position.
Binding control rack/
pump element
Open the cover (RQ/
RQV) or hexagon (RSV)
on the governor and
check with a nger on
the control rod that it
goes to the maximum
stop bracket.
(This applies to engines
without smoke limiter
on the governor hous-
ing.)
- Take the pump to a
Bosch workshop for
repair
- Preheat the engine
combustion chambers
by running the starter
motor with the stop
control in stop position
for about 15 seconds.
Then start in the usual
way.