GENERAL INSTRUCTIONS
SHOP MANUAL
Ch 0 page 29
• When disconnecting battery terminals, wait for approxi-
mately one minute after turning engine starter switch key
to "O" (OFF) position, and be sure to disconnect ground-
ing terminal; negative (-) terminal
first. Conversely, when connecting them, begin with posi-
tive (+) terminal and then grounding (-) terminal, Make
sure that all terminals are connected securely.
• Flammable hydrogen gas is generated when battery is
charged. Remove battery from machine, take it to a well
ventilated place, and remove battery caps, before charg-
ing it.
• After charging, tighten battery caps securely.
• After charging, secure battery back in machine. When
repairing or welding electrical system, wait for approxi-
mately one minute after turning engine starter switch key
"OFF." Then disconnect negative (-) terminal of battery to
stop flow of electricity.