14.8 Loading the Data (LOAD)
────────────────────────────────────────────────────
s128-4,5
NOTE
Auto Setup Function
When the power is switched on with a floppy disk or a PC card inserted, the
setting up of the 8841/42 is performed automatically by reading the setting
data file called "STARTUP.SET" and the evaluation area file called
"STARTUP.ARE"
on the floppy disk.
Waveform evaluation settings depend on "STARTUP.ARE"
The same measurement conditions can be simply established by using
this function.
Procedure 1
Screen: FILE
1. Press the FILE key to display the FILE screen.
2. Move the flashing cursor to MEDIA and select the FD
or
PC
function key.
3. Move the flashing cursor to
UTILITY
.
4. Select the
MK START UP
function key.
5. Select the
SETTING
function key.
Procedure 2
Screen: FILE
1. Press the FILE key to display the FILE screen.
2. Move the flashing cursor to MEDIA and select the FD
or
PC
function key.
3. Move the flashing cursor to
COMMAND
.
Move to the root directory, if the current directory is
not the root.
4. Select the
save
function key and save the setup data
file name as "STARTUP.SET" and area data file
name as "STARTUP.ARE".
・ The file saved to the root directory is found, then setup is performed. The
auto-setup file must be located in the root directory.
・ If "STARTUP.SET" is present on both the FD and PC cards, the FD file is
used.