7065Admin_Tools.fm Draft Document for Review August 30, 2007 12:59 am
252 IBM System Storage DS3000: Introduction and Implementation Guide
Figure 11-8 Media Scan Settings - Standard Settings
The change Media Scan window has two sections. In the first, you can suspend media scan
and set the scan duration, and in the second, you can enable or disable the redundancy
check.
Suspend Media Scan
To disable the media scan, check Suspend Media Scan and click OK. All media scan
functions will be disabled for all logical drives.
Edit scan duration days
To edit the scan duration, make sure Suspend Media Scan is unchecked and select the new
value in the Scan duration box. Click OK to save the changes.
Logical Drive Settings
If the media scan is active you can enable a Redundancy Check for individual logical drives.
1. Highlight the logical drive(s) you want to set, Figure 11-8.
2. To enable the media scan check Scan selected logical drives, choose with or without
redundancy check, and click OK
3. The changes will be saved on the storage subsystem, and you are informed (Figure 11-9
on page 253) when it is completed. Click OK to return to the Tools tab.