EasyManuals Logo

Tektronix Keithley SourceMeter 2470 Reference Manual

Tektronix Keithley SourceMeter 2470
995 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #342 background imageLoading...
Page #342 background image
Section
8: Triggering 2470 High Voltage SourceMeter Instrument
Reference Manual
8-44 2470-901-01 Rev. A / May 2019
Front-panel
icon
SCPI command
TSP command
Block description
:TRIGger:BLOCk:BRANch:ONCE (on page 12-155)
trigger.model.setblock() — trigger.BLOCK_BRANCH_ONCE
(on page
14-233)
This causes the
trigger model to
branch to a
specified building
block the first time
it is encountered in
the trigger model
:TRIGger:BLOCk:BRANch:ONCE:EXCLuded (on page 12-156)
trigger.model.setblock() —
trigger.BLOCK_BRANCH_ONCE_EXCLUDED (on page 14-234)
This causes the
trigger model to go
to a specified
building block every
time the trigger
model encounters
it, except for the
first time
:TRIGger:BLOCk:BUFFer:CLEar (on page 12-157)
trigger.model.setblock() — trigger.BLOCK_BUFFER_CLEAR
(on page
14-235)
This defines a
trigger model block
that clears the
reading buffer
:TRIGger:BLOCk:CONFig:NEXT (on page 12-158)
trigger.model.setblock() — trigger.BLOCK_CONFIG_NEXT
(on page
14-235)
This recalls the
settings at the next
index of a source or
measure
configuration list
:TRIGger:BLOCk:CONFig:PREVious (on page 12-159)
trigger.model.setblock() — trigger.BLOCK_CONFIG_PREV (on page
14-237)
This defines a
trigger model block
that recalls the
settings stored at
the previous index
in a source or
measure
configuration list
:TRIGger:BLOCk:CONFig:RECall (on page 12-160)
trigger.model.setblock() — trigger.BLOCK_CONFIG_RECALL
(on
page 14-239)
This recalls the
system settings
that are stored in a
source or measure
configuration list
:TRIGger:BLOCk:DELay:CONStant (on page 12-161)
trigger.model.setblock() — trigger.BLOCK_DELAY_CONSTANT (on
page 14-240)
This adds a
constant delay to
the execution of a
trigger model
:TRIGger:BLOCk:DELay:DYNamic (on page 12-162)
trigger.model.setblock() — trigger.BLOCK_DELAY_DYNAMIC
(on
page 14-241)
This adds a user
delay to the
execution of the
trigger model

Table of Contents

Other manuals for Tektronix Keithley SourceMeter 2470

Questions and Answers: