CHAPTER57 Reporting Information to External Party
Mediant 1000 Gateway & E-SBC | User's Manual
Field Description
Destination
Username
Before
Manipulation
[811]
Displays the original destination username (before manipulation, if any).
Note:
The field is optional and can be included in the CDR using the SBC CDR
Format tables.
The field is applicable to all CDR Report Types.
The field is applicable only to SBC signaling CDRs.
The maximum number of characters for Syslog tabular alignment is 20.
Destination
Username
[809]
Displays the destination username (after manipulation, if any).
Note:
The field is optional and can be included in the CDR using the SBC CDR
Format tables.
The field is applicable to all CDR Report Types.
The field is applicable only to SBC signaling CDRs.
The maximum number of characters for Syslog tabular alignment is 20.
Direct Media
[807]
Displays whether the call session flowed directly between the endpoints (i.e.,
Direct Media). The field is a string:
"yes": The call is a direct media call session.
"no": The call traversed the device.
Note:
The field is included in the default CDR.
The field is applicable to all CDR Report Types.
The field is applicable only to SBC signaling CDRs.
The default field title is "DirectMedia".
The maximum number of characters for Syslog tabular alignment is 11.
Endpoint
Type
[400]
Displays the endpoint type. The field is a string:
"NONE"
"FXO"
"FXS"
"ISDN"
"CAS"
"TRANSPARNT" (E1/T1 calls without D-channel / signaling)
"SBC" (SBC calls)
"TEST" (for Test Call calls)
"3WCONF" (three-way conferencing calls)
"SIPREC" (SIPRec calls)
"MOH" (Music-on-Hold calls)
Note:
The field is included in the default CDR.
The field is applicable to all CDR Report Types.
The field is applicable only to SBC signaling and Gateway CDRs.
The default field title is "EPTyp".
The maximum number of characters for Syslog tabular alignment is 10.